General Description
This power unit is specially designed for electric stacker,It is a typical power ascending and gravity descending system whose descending speed is automatically controlled by buit-in pressure compensating throttle valve.
Outline Dimension
Hydraulic circuit optional 010
Model Specifications
Special Notes
1. For diflerent flow rate pump.pressure and motor power.please check the ordering guidance.
2. This motor is based on gap working system S2=2 - 4min(continuous working time), so it cannot run continuously.
3. Before installation,the cylinder,oil pipe,joint and other hydraulic components must be cleaned and free from any impurities.
4. The viscosily of hydraulic oil should be 15-68cst and should be clean and tree of impurities.HiM46 hydraulic oil is recommended.
5. If you need manual oil discharge device for emergency,please specifywhen ordering.
6. Check that whether there is enough oil in the oil tank immediately after the first operating of the system.
7. The hydraulic oil should be replaced after the first 100 hours'use of the system, and change the oil every 3,000 hours after that.